WE HAVE SELECTED THE OPTIMAL ENGINEERING SOLUTION
Our regular client has once again approached us, this time with the task of carrying out work on a facility with an area of just under 200 м².
As a result of a detailed survey, we found out that the floor would be exposed to static loads of up to 2 tons per 1 м² and dynamic loads from forklifts. The main requirement of the customer was protection from moisture, dust, and wear.
The most optimal technical solution was chosen: a concrete floor with an average thickness of 12 cm, reinforced with plastic fiber. Most of the surface required hardening with a dry shake topping, while some areas were specified to remain without it (see details in the section below).