Our engineering in action
On the example of the floor arrangement for the largest transport and logistics center of Belarus "Prilesye"

TOPPING FLOOR FOR A PRODUCTION FACILITY IN THE RAMENSKY DISTRICT OF THE MOSCOW AREA

WE HAVE SAVED FOR THE CLIENT 195 400
20%Economy
Topping floor for an industrial facility in the Ramensky district of the Moscow area

FLOOR ENGINEERING CONSTRUCTION Topping floor for an industrial facility in the Ramensky district of the Moscow area

Moscow Region, Ramensky Municipal District, Kulakovo Village
Characteristics and description
Company name
TechGarant LLC
The purpose of the floor and the room itself
Topping floor for an industrial facility in the Ramensky district of the Moscow area
Type of floor
topping floors
Thickness of the concrete layer
12 cm
Room area
198.8 m²

Customer needs AND THE OPTIMAL ENGINEERING SOLUTION

factors taken into account when developing the floor design

WE HAVE SELECTED THE OPTIMAL ENGINEERING SOLUTION

Our regular client has once again approached us, this time with the task of carrying out work on a facility with an area of just under 200 м².

As a result of a detailed survey, we found out that the floor would be exposed to static loads of up to 2 tons per 1 м² and dynamic loads from forklifts. The main requirement of the customer was protection from moisture, dust, and wear.

The most optimal technical solution was chosen: a concrete floor with an average thickness of 12 cm, reinforced with plastic fiber. Most of the surface required hardening with a dry shake topping, while some areas were specified to remain without it (see details in the section below).

Terms of work
Number of days for all work: 30
Requirements for the quality of work
Floors must comply with SNiP 2.03. 13-88
Appearance of floors
Must look presentable
Durability
Service life of floors without repair (years): 10
Total cost
Budget within the framework of: 977 200 ₽
Topping floor for an industrial facility in the Ramensky district of the Moscow area: The object before the start of work
The object before the start of work

Floor arrangement ACCORDING TO THE ENGINEERING SOLUTION FOR THE OBJECT: TechGarant LLC

how we implemented this floor design

FEATURES OF WORKS

In several places, the condition of the subbase was poor – there was no concrete. The customer first added sand to these areas on their own, and then, after receiving the reinforcement program from us, prepared the frame.

In some of the rooms, we poured the floor without topping and 2 cm lower than in the rest of the area, where the client was going to lay the tiles without our involvement. We made the layer thinner to keep the final surface level even everywhere.

We covered the finished painted walls with protective film, but unfortunately, some spots still got stained. We resolved the issue by arranging with local finishers to touch up those areas after we were done.

OUR RESULTS

Thanks to us, this client company is getting more and more industrial facilities with decent floors. We are happy and ready to keep going.

Stages of implementation engineering design of the floor

engineering design of the floor
1.jpg
The walls have been covered with a film
2.jpg
The reinforcement frame is ready
3.jpg
Concrete hardener received
4.jpg
Concrete pump has arrived
5.jpg
Mixer is being filled with concrete mix at the plant
6.jpg
Pouring has begun
7.jpg
Close-up of concrete mix
8.jpg
Pouring is coming to an end
9.jpg
Cutting seams
10.jpg
Checking the depth of seams

The result of floor engineeringDELIVERED ON TIME, STANDARD, TECHNOLOGICAL INDUSTRIAL FLOORS AT THE FACILITY TechGarant LLC

SEE THE RESULT OF OUR WORK
result-ip-pershin-tekhgarant-kulakovo-ramenskij-rajon.jpg

READ REVIEWS OUR SATISFIED CUSTOMERS

Reviews that we managed to collect between production cycles at our facilities

ReviewsABOUT THE PROFTEHPOL PROJECT

We are well aware that reviews of companies can be very different. Working in the construction market for more than 15 years, we have faced various situations.

We have both satisfied customers and those who are not. But, there is one important thing: we always bring the cycles of our provision to the end. If a client has problems, then we do not leave him with them, but settle them to a full and final conclusion.

Working with us, you can be sure that we will make you an industrial floor that is exactly right for the task for which you needed it.

Thanks to a good knowledge of the technology of industrial floors, we have gathered a lot of practical experience in using floor structures in various difficult places. We solve non-trivial problems and often, when we take an order, 3-4 companies have already tried to take it before us, but refused due to the complexity of the object.

Our clients Which we are proud of

for which we have made good floors
Legal informationSociety Limited Liability "PROFTECHENGINEERING" Shareholdt International consumer society "GOLDEN AXIS"TIN 9709064635CHECKPOINT 770901001OGRN 1207700295406Legal address:109147, Moscow, B.Andronevskaya str., 23, building 1, floor 8, room 4, office of PROFTEHPOL company
POSTAL DETAILSActual address:109147, Moscow, B.Andronevskaya str., 23, building 1, floor 8, room 4, office of PROFTEHPOL companyPhone number for details:8 800 550 90 72E-mail:info@proftechpol.ru
Financial detailsCurrent account: 40702810870010234730MOSCOW BRANCH OF JSC CB "MODULBANK" MoscowBIC 044525092Correspondent account 30101810645250000092CEO of Nazyrov Anton